{"id":275997,"date":"2021-05-24T16:07:28","date_gmt":"2021-05-24T14:07:28","guid":{"rendered":"https:\/\/weenat.com\/sonde-capacitive-installation\/"},"modified":"2025-09-26T17:19:30","modified_gmt":"2025-09-26T15:19:30","slug":"sonda-capacitiva-instalacion","status":"publish","type":"post","link":"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/","title":{"rendered":"Los secretos para instalar bien la sonda capacitiva"},"content":{"rendered":"<p>[et_pb_section fb_built=\u00bb1&#8243; _builder_version=\u00bb4.16&#8243; custom_margin=\u00bb||3%||false|false\u00bb custom_padding=\u00bb60px||0%||false|false\u00bb custom_padding_tablet=\u00bb10%||5%||false|false\u00bb custom_padding_phone=\u00bb15%||10%||false|false\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_row _builder_version=\u00bb4.16&#8243; max_width=\u00bb1100px\u00bb module_alignment=\u00bbcenter\u00bb custom_padding=\u00bb0px|5%|0px|5%|false|true\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_column type=\u00bb4_4&#8243; _builder_version=\u00bb4.16&#8243; global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_text _builder_version=\u00bb4.24.0&#8243; custom_margin=\u00bb0px||0px||true|false\u00bb custom_padding=\u00bb||30px||false|false\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<p>La instalaci\u00f3n de la<strong> <a href=\"\/es\/sensores\/sonda-capacitiva\/\">sonda capacitiva<\/a><\/strong> es la etapa m\u00e1s importante para<strong> <a href=\"\/es\/controla-riego-precision\/\">mejorar el rendimiento del riego<\/a><\/strong>, porque si la colocas mal, obtendr\u00e1s datos de <strong>mala calidad<\/strong>. Y si te basas en datos incorrectos, estar\u00e1s corriendo el riesgo de tomar malas decisiones.<\/p>\n<p>La fiabilidad de las mediciones de la sonda capacitiva depende m\u00e1s de la calidad de la <strong>instalaci\u00f3n<\/strong> que del propio sensor. De hecho, es poco habitual que dos sondas colocadas una junto a la otra den <strong>exactamente<\/strong> la misma medida, sobre todo si se han instalado de manera diferente.<\/p>\n<p>Para instalarlas bien, sigue las instrucciones y utiliza nuestra <strong>lista de verificaciones<\/strong> paso a paso.<\/p>\n<p><strong>\u00bfEmpezamos?<\/strong><\/p>\n<p>[\/et_pb_text][et_pb_image src=\u00bbhttps:\/\/preprod.weenat.com\/wp-content\/uploads\/2023\/10\/Installation-Sonde-capacitive-weenat.webp\u00bb alt=\u00bbLa sonde capacitive connect\u00e9e Weenat facilite le pilotage de l&#8217;irrigation\u00bb title_text=\u00bbInstallation-Sonde-capacitive-weenat\u00bb _builder_version=\u00bb4.24.0&#8243; _module_preset=\u00bbdefault\u00bb hover_enabled=\u00bb0&#8243; border_radii=\u00bbon|10px|10px|10px|10px\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb box_shadow_style=\u00bbpreset3&#8243; sticky_enabled=\u00bb0&#8243;][\/et_pb_image][et_pb_text module_id=\u00bbou\u00bb _builder_version=\u00bb4.24.0&#8243; text_font_size=\u00bb1.4em\u00bb custom_margin=\u00bb50px||20px||false|false\u00bb custom_padding=\u00bb||0px|||\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<h2><span>\u00bfD\u00f3nde es mejor colocar la sonda capacitiva?<\/span><\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=\u00bb4.24.0&#8243; custom_margin=\u00bb28px||28px||true|false\u00bb custom_padding=\u00bb|5%||0%|false|false\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<h3><strong>\u2714<\/strong><strong> Elige un suelo representativo<\/strong><\/h3>\n<p><span>La sonda capacitiva debe instalarse en una zona en la que el tipo y el trabajo del suelo sean representativos de tus terrenos. Si labras en la mayor\u00eda de tus terrenos, col\u00f3cala en uno en el que hayas labrado el suelo.<\/span><\/p>\n<h3><strong>\u2714<\/strong><strong> Aseg\u00farate de que la vegetaci\u00f3n sea representativa<\/strong><\/h3>\n<p><span>Lo mejor es elegir una zona en la que el cultivo sea homog\u00e9neo y representativo del terreno (variedad, estado de la vegetaci\u00f3n, etapa de cultivo, densidad, estado sanitario, etc.). Por ejemplo, evita los bordes del terreno. \u00a1Cuidado! En el momento de la instalaci\u00f3n de la sonda capacitiva, no alteres demasiado el cultivo, porque podr\u00eda afectar a la representatividad de la zona medida.<\/span><\/p>\n<h3><strong>\u2714<\/strong><strong> Identifica una zona de riego medio<\/strong><\/h3>\n<p><span>La zona controlada debe ser representativa del resto de terrenos regados. Elige una zona situada en la media de las dosis proporcionadas por el sistema de riego. Para facilitar el control, lo mejor es colocar la sonda capacitiva en el terreno que primero riegue el sistema.<\/span><\/p>\n<p><span style=\"color: #6f66f7;\"><em><strong>Consejo:<\/strong><\/em><\/span><em> instala la sonda capacitiva en el terreno que primero riegue el sistema.<\/em><\/p>\n<h3><strong>\u2714<\/strong><strong> Adapta la instalaci\u00f3n en funci\u00f3n del sistema de riego<\/strong><\/h3>\n<h4>\u27a1\ufe0f<em> Riego por aspersi\u00f3n<\/em><\/h4>\n<p><span>En caso de riego por aspersi\u00f3n, el objetivo es asegurarse de que la dosis aplicada hidrate el suelo lo suficiente con respecto a la frecuencia de riego, por lo que es necesario realizar mediciones a diferentes profundidades para tener una vista de conjunto del perfil.<\/span><\/p>\n<h4>\u27a1\ufe0f<em> Riego localizado<\/em><\/h4>\n<p><span>En caso de riego por goteo, instala la sonda en la periferia de la zona de influencia del gotero, a medio camino entre este y la hilera. Se trata del lugar en el que las plantas se abastecen de agua, por lo que es el sitio perfecto para controlar la cantidad de agua suministrada y el consumo de las plantas. As\u00ed podr\u00e1s vigilar las variaciones de dimensi\u00f3n del bulbo h\u00famedo.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_text][et_pb_image src=\u00bbhttps:\/\/preprod.weenat.com\/wp-content\/uploads\/2024\/04\/riego-adecuado-execiso-insuficiente.webp\u00bb alt=\u00bbSch\u00e9ma d&#8217;installation d&#8217;une sonde pour piloter l&#8217;irrigation\u00bb title_text=\u00bbinstallation-sonde-irrigation\u00bb _builder_version=\u00bb4.16&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][\/et_pb_image][et_pb_text _builder_version=\u00bb4.24.0&#8243; custom_margin=\u00bb28px||28px||true|false\u00bb custom_padding=\u00bb|5%||0%|false|false\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<h3><strong>\u2714<\/strong><strong> Optimiza la ubicaci\u00f3n en funci\u00f3n de tus cultivos<\/strong><\/h3>\n<p><span>La sonda debe colocarse cerca del sistema de ra\u00edces, para estimar su consumo de agua con la mayor precisi\u00f3n, pero tambi\u00e9n dentro de una zona de vegetaci\u00f3n representativa, para tener en cuenta la cantidad de agua infiltrada en el suelo.<\/span><\/p>\n<p><strong>Ejemplos de ubicaciones recomendadas:<\/strong><\/p>\n<p>\u27a1\ufe0f <em>cereales: en la hilera;<\/em><em><br \/><\/em>\u27a1\ufe0f <em>ma\u00edz\/sorgo: a 8-10\u00a0cm de la hilera;<\/em><em><br \/><\/em>\u27a1\ufe0f <em>patata: a 8-10\u00a0cm del tub\u00e9rculo.<\/em><\/p>\n<p>[\/et_pb_text][et_pb_text module_id=\u00bbcomment\u00bb _builder_version=\u00bb4.24.0&#8243; text_font_size=\u00bb1.4em\u00bb custom_margin=\u00bb50px||20px||false|false\u00bb custom_padding=\u00bb||0px|||\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<h2>\u00bfC\u00f3mo se instala la sonda capacitiva?<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=\u00bb4.24.0&#8243; custom_margin=\u00bb28px||28px||true|false\u00bb custom_padding=\u00bb|5%||0%|false|false\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<h3><strong>\u2714<\/strong><strong> Prepara el material<\/strong><\/h3>\n<p><span>Para instalar la sonda capacitiva, necesitar\u00e1s:<\/span><\/p>\n<p>\u27a1\ufe0f <em>una ahoyadora;<\/em><em><br \/><\/em>\u27a1\ufe0f <em>un cubo;<\/em><em><br \/><\/em>\u27a1\ufe0f <em>agua.<\/em><\/p>\n<h3><strong>\u2714<\/strong><strong> Cava un agujero<\/strong><\/h3>\n<p><span>Con la ahoyadora, excava un agujero de 38-40\u00a0mm de di\u00e1metro hasta alcanzar la profundidad deseada. Es muy importante que no quede espacio entre el suelo y la sonda. Es imprescindible que la ahoyadora tenga las dimensiones adecuadas.<\/span><\/p>\n<p><span>Retira la tierra y ve coloc\u00e1ndola en el cubo, hasta alcanzar una profundidad correspondiente a la longitud de la sonda.<\/span><\/p>\n<p><span>\u00a1Cuidado! No excaves m\u00e1s de lo necesario para evitar formar una bolsa de aire que perjudicar\u00eda la calidad de las mediciones.<\/span><\/p>\n<p><span style=\"color: #6f66f7;\"><strong><em>Consejo:<\/em><\/strong><\/span><em> ser\u00e1 m\u00e1s f\u00e1cil instalar la sonda capacitiva si el suelo est\u00e1 mojado.<\/em><\/p>\n<h3><strong>\u2714<\/strong><strong> Prepara el barro<\/strong><\/h3>\n<p>&nbsp;<\/p>\n<p>Mezcla agua y tierra en el cubo para formar barro con el que garantizar un buen contacto entre el suelo y el <strong><a href=\"\/es\/sensores\/sonda-capacitiva\/\">sensor<\/a><\/strong>.<\/p>\n<h3><strong>\u2714<\/strong><strong> Instala el sensor<\/strong><\/h3>\n<p><span>Vierte cuidadosamente parte del barro en el agujero para evitar la formaci\u00f3n de bolsas de aire y, despu\u00e9s, hunde la sonda capacitiva sin forzarla. Por \u00faltimo, sella el agujero vertiendo el barro restante.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span>Tambi\u00e9n puedes regar el agujero para arrastrar tierra adentro. Lo importante es que el agujero se llene por completo para garantizar un buen contacto entre la sonda y el suelo durante toda la temporada.<\/span><\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=\u00bb4.24.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_column type=\u00bb4_4&#8243; _builder_version=\u00bb4.24.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_text module_id=\u00bbvideo\u00bb _builder_version=\u00bb4.24.0&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<h2><span>Ver c\u00f3mo instalar la sonda capacitiva de Weenat en v\u00eddeo<\/span><\/h2>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=\u00bb4.17.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_column type=\u00bb4_4&#8243; _builder_version=\u00bb4.17.4&#8243; _module_preset=\u00bbdefault\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_code _builder_version=\u00bb4.24.0&#8243; _module_preset=\u00bbdefault\u00bb width=\u00bb100%\u00bb module_alignment=\u00bbcenter\u00bb border_radii=\u00bbon|10px|10px|10px|10px\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/oGtQm0Tq53k?si=GiQ-zHGGd8mbX8LB\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>[\/et_pb_code][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=\u00bb1&#8243; _builder_version=\u00bb4.16&#8243; custom_padding=\u00bb0%||3%||false|false\u00bb locked=\u00bboff\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_row custom_padding_last_edited=\u00bboff|desktop\u00bb _builder_version=\u00bb4.24.0&#8243; background_color=\u00bbrgba(1,173,190,0.1)\u00bb custom_padding=\u00bb3vw|5%|3vw|5%|true|false\u00bb custom_padding_tablet=\u00bb0px|5%|60px|5%|false|false\u00bb border_radii=\u00bbon|10px|10px|10px|10px\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_column type=\u00bb4_4&#8243; _builder_version=\u00bb4.16&#8243; global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][et_pb_text _builder_version=\u00bb4.24.0&#8243; text_font=\u00bb|600|||||||\u00bb text_text_color=\u00bb#0172A4&#8243; custom_margin=\u00bb28px||28px||true|false\u00bb custom_padding=\u00bb|5%||0%|false|false\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<p>M\u00c1S INFORMACI\u00d3N<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=\u00bb4.24.0&#8243; module_alignment=\u00bbcenter\u00bb custom_padding=\u00bb8px|||||\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<h2 style=\"text-align: left;\">Pide tu gu\u00eda totalmente gratis para ganar en precisi\u00f3n al regar<\/h2>\n<p style=\"text-align: left;\"><strong>Se acab\u00f3 eso de regar a ojo<\/strong>. Descubre paso a paso c\u00f3mo aumentar el rendimiento del riego gracias a las sondas de control.<\/p>\n<p>[\/et_pb_text][et_pb_image src=\u00bbhttps:\/\/preprod.weenat.com\/wp-content\/uploads\/2024\/04\/20240322_Signature_Livre_Blanc_Irrigation_ES.webp\u00bb title_text=\u00bb20240307_bandeau_Livre_Blanc_Irrigation-weenat\u00bb url=\u00bbhttps:\/\/l45lnxy9q26.typeform.com\/to\/tLcAlAzN?utm_source=blog&#038;utm_medium=banner&#038;utm_campaign=livre-blanc-irrigation&#038;utm_content=installation-sonde-capa\u00bb _builder_version=\u00bb4.24.0&#8243; _module_preset=\u00bbdefault\u00bb module_alignment=\u00bbcenter\u00bb custom_margin=\u00bb||0px||false|false\u00bb custom_padding=\u00bb10px||0px||false|false\u00bb border_radii=\u00bboff|1px|1px|1px|1px\u00bb border_color_left=\u00bb#000000&#8243; global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb][\/et_pb_image][et_pb_code _builder_version=\u00bb4.24.0&#8243; _module_preset=\u00bbdefault\u00bb module_alignment=\u00bbleft\u00bb global_colors_info=\u00bb{}\u00bb theme_builder_area=\u00bbpost_content\u00bb]<\/p>\n<div data-tf-live=\"01HTJAB7TY98XG0SVRBYYK8AES\"><\/div>\n<p><script src=\"\/\/embed.typeform.com\/next\/embed.js\"><\/script>[\/et_pb_code][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>La instalaci\u00f3n de su sensor capacitivo es el paso M\u00c1S IMPORTANTE para mejorar el rendimiento de su riego. Porque un sensor capacitivo mal instalado dar\u00e1 datos de baja calidad.<\/p>\n","protected":false},"author":4,"featured_media":86523,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[141],"tags":[],"class_list":["post-275997","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-control-del-riego"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00bfC\u00f3mo se instala la sonda capacitiva? | Weenat<\/title>\n<meta name=\"description\" content=\"Para controlar el riego con precisi\u00f3n, es clave el momento de instalar la sonda capacitiva. A continuaci\u00f3n, te presentamos nuestros consejos para hacerlo bien.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfC\u00f3mo se instala la sonda capacitiva? | Weenat\" \/>\n<meta property=\"og:description\" content=\"Para controlar el riego con precisi\u00f3n, es clave el momento de instalar la sonda capacitiva. A continuaci\u00f3n, te presentamos nuestros consejos para hacerlo bien.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/\" \/>\n<meta property=\"og:site_name\" content=\"Weenat\" \/>\n<meta property=\"article:published_time\" content=\"2021-05-24T14:07:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-26T15:19:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/preprod.weenat.com\/wp-content\/uploads\/2021\/03\/sonde-capacitive-pour-irrigation-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"533\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Emeline FLORES\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Emeline FLORES\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/\",\"url\":\"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/\",\"name\":\"\u00bfC\u00f3mo se instala la sonda capacitiva? | Weenat\",\"isPartOf\":{\"@id\":\"https:\/\/preprod.weenat.com\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/preprod.weenat.com\/wp-content\/uploads\/2021\/03\/sonde-capacitive-pour-irrigation-1.jpg\",\"datePublished\":\"2021-05-24T14:07:28+00:00\",\"dateModified\":\"2025-09-26T15:19:30+00:00\",\"author\":{\"@id\":\"https:\/\/preprod.weenat.com\/es\/#\/schema\/person\/ac33bec4796712530eaad5a4e77f7262\"},\"description\":\"Para controlar el riego con precisi\u00f3n, es clave el momento de instalar la sonda capacitiva. A continuaci\u00f3n, te presentamos nuestros consejos para hacerlo bien.\",\"breadcrumb\":{\"@id\":\"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#primaryimage\",\"url\":\"https:\/\/preprod.weenat.com\/wp-content\/uploads\/2021\/03\/sonde-capacitive-pour-irrigation-1.jpg\",\"contentUrl\":\"https:\/\/preprod.weenat.com\/wp-content\/uploads\/2021\/03\/sonde-capacitive-pour-irrigation-1.jpg\",\"width\":800,\"height\":533,\"caption\":\"La sonde capacitive connect\u00e9e Weenat facilite le pilotage de l'irrigation\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Weenat\",\"item\":\"https:\/\/preprod.weenat.com\/es\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Los secretos para instalar bien la sonda capacitiva\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/preprod.weenat.com\/es\/#website\",\"url\":\"https:\/\/preprod.weenat.com\/es\/\",\"name\":\"Weenat\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/preprod.weenat.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/preprod.weenat.com\/es\/#\/schema\/person\/ac33bec4796712530eaad5a4e77f7262\",\"name\":\"Emeline FLORES\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/preprod.weenat.com\/es\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/814f079c36357c3593a70e7912b0c1da85733259edf2bb1d783d4a5aedbbd710?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/814f079c36357c3593a70e7912b0c1da85733259edf2bb1d783d4a5aedbbd710?s=96&d=mm&r=g\",\"caption\":\"Emeline FLORES\"},\"url\":\"https:\/\/preprod.weenat.com\/es\/author\/emeline\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u00bfC\u00f3mo se instala la sonda capacitiva? | Weenat","description":"Para controlar el riego con precisi\u00f3n, es clave el momento de instalar la sonda capacitiva. A continuaci\u00f3n, te presentamos nuestros consejos para hacerlo bien.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"es_ES","og_type":"article","og_title":"\u00bfC\u00f3mo se instala la sonda capacitiva? | Weenat","og_description":"Para controlar el riego con precisi\u00f3n, es clave el momento de instalar la sonda capacitiva. A continuaci\u00f3n, te presentamos nuestros consejos para hacerlo bien.","og_url":"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/","og_site_name":"Weenat","article_published_time":"2021-05-24T14:07:28+00:00","article_modified_time":"2025-09-26T15:19:30+00:00","og_image":[{"width":800,"height":533,"url":"https:\/\/preprod.weenat.com\/wp-content\/uploads\/2021\/03\/sonde-capacitive-pour-irrigation-1.jpg","type":"image\/jpeg"}],"author":"Emeline FLORES","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Emeline FLORES","Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/","url":"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/","name":"\u00bfC\u00f3mo se instala la sonda capacitiva? | Weenat","isPartOf":{"@id":"https:\/\/preprod.weenat.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#primaryimage"},"image":{"@id":"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#primaryimage"},"thumbnailUrl":"https:\/\/preprod.weenat.com\/wp-content\/uploads\/2021\/03\/sonde-capacitive-pour-irrigation-1.jpg","datePublished":"2021-05-24T14:07:28+00:00","dateModified":"2025-09-26T15:19:30+00:00","author":{"@id":"https:\/\/preprod.weenat.com\/es\/#\/schema\/person\/ac33bec4796712530eaad5a4e77f7262"},"description":"Para controlar el riego con precisi\u00f3n, es clave el momento de instalar la sonda capacitiva. A continuaci\u00f3n, te presentamos nuestros consejos para hacerlo bien.","breadcrumb":{"@id":"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#primaryimage","url":"https:\/\/preprod.weenat.com\/wp-content\/uploads\/2021\/03\/sonde-capacitive-pour-irrigation-1.jpg","contentUrl":"https:\/\/preprod.weenat.com\/wp-content\/uploads\/2021\/03\/sonde-capacitive-pour-irrigation-1.jpg","width":800,"height":533,"caption":"La sonde capacitive connect\u00e9e Weenat facilite le pilotage de l'irrigation"},{"@type":"BreadcrumbList","@id":"https:\/\/preprod.weenat.com\/es\/sonda-capacitiva-instalacion\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Weenat","item":"https:\/\/preprod.weenat.com\/es\/"},{"@type":"ListItem","position":2,"name":"Los secretos para instalar bien la sonda capacitiva"}]},{"@type":"WebSite","@id":"https:\/\/preprod.weenat.com\/es\/#website","url":"https:\/\/preprod.weenat.com\/es\/","name":"Weenat","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/preprod.weenat.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/preprod.weenat.com\/es\/#\/schema\/person\/ac33bec4796712530eaad5a4e77f7262","name":"Emeline FLORES","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/preprod.weenat.com\/es\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/814f079c36357c3593a70e7912b0c1da85733259edf2bb1d783d4a5aedbbd710?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/814f079c36357c3593a70e7912b0c1da85733259edf2bb1d783d4a5aedbbd710?s=96&d=mm&r=g","caption":"Emeline FLORES"},"url":"https:\/\/preprod.weenat.com\/es\/author\/emeline\/"}]}},"_links":{"self":[{"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/posts\/275997","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/comments?post=275997"}],"version-history":[{"count":1,"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/posts\/275997\/revisions"}],"predecessor-version":[{"id":286712,"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/posts\/275997\/revisions\/286712"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/media\/86523"}],"wp:attachment":[{"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/media?parent=275997"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/categories?post=275997"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/preprod.weenat.com\/es\/wp-json\/wp\/v2\/tags?post=275997"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}